brake fluid gear flow meter
email: porter@microflowmeter.com Shanghai JSN Micro Flow Meter CO.,LTD is main flowmetering equipment R&D and production company. The company"s flowmeter andgear pump in scientific research, development, production status.After severaldecades of reform and development, JSN has formed a company model ofindependent development, production, testing, sales and service integration.70% of its products are exported to foreign countries, and have undertakenmajor projects in China, and key enterprises in the industry. Pump supportingprojects. It has been promoted and applied in various engines, polyurethane,dispensing, chemical, lubrication, chemical fiber and other industries inChina.Main products: micro flow meter,oval gearflow meter ,coriolis mass flow meter,electromagnetic flow meter,piston flowmeter,spur gear flow meter,gear pump,gear metering pump etc.

brake fluid gear flow meter
Ovalgear flow meter is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.
Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

brake fluid gear flow meter
Ovalgear flow meter Through the rotation of the gear cavity, through a series ofdeceleration and speed ratio adjustment mechanism, directly connected with theindicator on the instrument panel, and through the mechanical counter for thetotal display. Or remote display is mainly through The decelerated gear drivesthe permanent magnet to rotate so that the contacts of the spring relay (Hallsensor) are closed or opened synchronously at the same rotation frequency asthe permanent magnet, thereby sending one electric pulse to the other displayinstrument.

brake fluid gear flow meter
Item | model | K-factor | The minimum flow | Flow range | Connection size |
Gear flow meter | CX-G0.025-P-AL | 0.025ml | 0.001L/Min | 0.004~1 L/min | G1/8 |
gear flow meter | CX-G0.025-P-SS | 0.025ml | 0.001L/Min | 0.004~1 L/min | G1/8 |
gear flow meter | CX-G0.04-P-AL | 0.04ml | 0.004L/min | 0.01~2L/min | G1/4 |
gear flow meter | CX-G0.04-P-SS | 0.04ml | 0.004L/min | 0.01~2L/min | G1/4 |
gear flow meter | CX-G0.1-P-AL | 0.1ml | 0.008L/min | 0.02~4L/min | G3/8 |
gear flow meter | CX-G0.1-P-SS | 0.1ml | 0.008L/min | 0.02~4L/min | G3/8 |
gear flow meter | CX-G0.2-P-AL | 0.245ml | 0.01L/Min | 0.08~8L/min | G3/8 |
gear flow meter | CX-G0.2-P-SS | 0.245ml | 0.01L/Min | 0.08~8L/min | G3/8 |
gear flow meter | CX-G0.4-P-AL | 0.4ml | 0.01L/Min | 0.1~20L/min | G1/2 |
gear flow meter | CX-G0.4-P-SS | 0.4ml | 0.01L/Min | 0.1~20L/min | G1/2 |
gear flow meter | CX-G1-P-AL | 1ml | 0.02L/Min | 0.2~40L/min | G1/2 |
gear flow meter | CX-G1-P-SS | 1ml | 0.02L/Min | 0.2~40L/min | G1/2 |
gear flow meter | CX-G2-P-AL | 2ml | 0.04L/Min | 0.5-60L/min | G3/4 |
gear flow meter | CX-G2-P-SS | 2ml | 0.04L/Min | 0.5-60L/min | G3/4 |
Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized
a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.
b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.
c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.
d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.